EIFS & Dryvit Restoration in Decatur
Much of the office and medical space around Decatur from the 1980s and 1990s was clad in EIFS, and plenty of it is barrier EIFS with no way to drain. We repair, reseal, recoat and, where it makes sense, convert those facades so they stay dry.
- EIFS & Dryvit repair
- Joint & sealant renewal
- Facade recoats
- Drainable conversions
Request a commercial quote
Decatur commercial stucco & EIFS. Property managers, boards, owners & builders.
Barrier EIFS needs a different repair
EIFS is foam board, a reinforced base coat and a thin finish, and it repairs very differently from cement stucco. Older barrier systems, common on professional and medical office buildings in and around Decatur, were designed to stop all water at the surface. When the sealant at a window or panel joint fails, water that gets past the face has nowhere to go but into the sheathing.
Restoration starts with finding those wet areas. We take moisture readings at joints and terminations, open any section where the substrate is damaged, replace the sheathing and rebuild the foam, mesh and base coat so the repair ties into the surrounding system. Joints are then resealed with the correct backer rod and sealant, and the elevation is recoated so the repair blends in.
On buildings with recurring problems, we will talk through a drainable conversion at the worst elevations or a re-clad, and we will be straightforward about when repair plus a sealant program is the better value. Every option starts with an envelope survey, because the readings decide the scope.

EIFS & Dryvit restoration in Decatur
Most EIFS problems come down to water at the edges or damage to a soft face. The scope depends on whether the substrate behind is still dry.
Wet substrate repair
Wet sections are cut out, damaged sheathing replaced with glass-mat gypsum board, and the wall rebuilt with new board, mesh, base coat and finish.
Joint & sealant renewal
Failed sealant at windows, storefronts and panel joints is replaced with backer rod and an EIFS-compatible sealant against a sound edge.
Facade recoats
A new finish coat over sound EIFS renews color and texture across an entire elevation or building without removing the system.
Barrier to drainable conversion
Failing barrier EIFS is removed and replaced with a drainable system over a weather barrier, elevation by elevation if needed.
Impact damage
Dents and punctures at entrances, loading areas and ground-floor corners are cut back, rebuilt with heavier mesh where needed and blended in.
Below-grade foam & termites
Foam board run into soil or under pavement gives termites a hidden path. We cut it back above grade and repair damaged framing.
Choosing the right EIFS scope
If moisture readings are low and damage is local, section repairs with new sealant joints and a matched finish are usually the right answer. If the facade has been patched many times or faded unevenly, a recoat across the elevation gives a uniform look and helps a dated building show better to tenants and prospects.
When barrier EIFS shows wet readings in many places, repairing spot by spot often just moves the problem. Converting to a drainable system, or to hard coat stucco or fiber cement on some elevations, can be the better long-term choice. We explain the options with readings and photos in front of you, separate urgent work from what can be phased, and document any change in scope for your approval before we proceed.
| Scope | Best for | Result |
|---|---|---|
| Section repair | Local damage, dry substrate | Blended to corners |
| Joint renewal | Failed sealant, sound wall | Edges closed |
| Facade recoat | Patched or faded elevations | Uniform building |
| Drainable conversion | Widespread wet barrier EIFS | New drainable system |
How an EIFS restoration runs
Restorations run elevation by elevation, so tenants and residents keep their entrances, parking and daily routine.
Identify & survey
We confirm whether the facade is barrier or drainable EIFS and take moisture readings to find the edges of any wet area on each elevation.
- System identified
- Readings mapped by elevation
- Photo documentation
Remove & rebuild
Damaged EIFS and wet sheathing come out. New sheathing, weather barrier and insulation board go in, with flashing corrected at the leak.
- Wet sheathing replaced
- Flashing corrected
- Foam kept above grade
Mesh, coat & finish
Base coat and reinforcing mesh are lapped into the existing wall, joints are sealed, and the finish is matched or the elevation recoated.
- Mesh lapped into old work
- Compatible materials
- Matched finish
Not sure if the building is EIFS or stucco?
EIFS sounds hollow and feels softer than cement stucco when tapped. We confirm it on the first site walk.
Decatur's EIFS generation
EIFS spread through Metro Atlanta in the 1980s and 1990s, and Decatur's professional offices, medical buildings and early condominiums show it.
Those buildings are now three or four decades into their service life. The finish has chalked, the original sealant is long past due, and terminations at grade and at roof edges were often detailed in ways that hold water. We see the same patterns repeatedly on medical and professional offices along North Decatur Road and on older buildings near downtown, which helps us scope them accurately and price them fairly.
Wet foam & sheathing
Sections that read wet are opened, the board replaced and the EIFS rebuilt to tie into sound material.
Terminations at grade
EIFS run down into soil or paving wicks water; we cut it back and terminate it properly.
Chalked, dated finish
A recoat restores color and texture over sound EIFS without removing the system.
- Downtown Decatur
- North Decatur
- Clairemont Avenue
- Church Street
- Druid Hills
- Emory area
- Tucker
- Clarkston
- Avondale Estates
- Scottdale
- Brookhaven
EIFS & Dryvit FAQ for Decatur property owners
What Decatur owners and managers ask about older EIFS facades.
Our Decatur office building has EIFS. Does changing its color need approval?
We manage a medical office near North Decatur Road. Can you work while patients are being seen?
Can EIFS be repaired, or does it have to be replaced?
What is the difference between barrier and drainable EIFS?
Is Dryvit the same as EIFS?
Why do termites matter on EIFS buildings?
Restore your Decatur EIFS facade
Tell us what the building is showing. We will survey the EIFS, find the wet areas and write a restoration scope.